    ممكن مساعدة بخصوص جهاز Phoenix bd
    أي معلومات عنه مبدأه، طريقة عمله....

    وشكرا
    http://www.filesgate.com/up81/w22/20.../_61447337.gif

  • #2
    حياك الله أختي الكريمة ....




    تفضلي هذا هو مبدأ عمل الجهاز ...

    PRINCIPLES OF THE PROCEDURE

    A maximum of 100 identification and antimicrobial susceptibility tests can be performed in the Phoenix instrument at a time using Phoenix ID/AST combination panels. A sealed and self-inoculating molded polystyrene tray, with 136 micro-wells containing dried reagents, serves as the Phoenix disposable. The combination panel includes an ID side with dried substrates for bacterial identification, an AST side with varying concentrations of antimicrobial agents, and growth and fluorescent controls at appropriate well locations. The Phoenix system utilizes an optimized colorimetric redox indicator for AST, and a variety of colorimetric and fluorometric indicators for ID. The AST Broth is cation-adjusted (e.g., Ca++ and Mg++) to optimize susceptibility testing performance.
    The Phoenix panel is comprised of a 51 well ID side and an 85 well AST side. The ID side contains 45 wells with dried biochemical substrates and 2 fluorescent control wells. The AST side contains 84 wells with dried antimicrobial agents and 1 growth control well. Panels are available as ID only (Phoenix™ NID Panels, Phoenix™ PID Panels), AST only (Phoenix™ NMIC Panels, Phoenix™ PMIC Panels), or ID/AST combination (Phoenix™ NMIC/ID Panels, Phoenix™ PMIC/ID Panels). Unused wells are reserved for future use.
    Phoenix panels are inoculated with a standardized inoculum. Organism suspensions must be prepared only with the BBL™ CrystalSpec™ or BD PhoenixSpec™ Nephelometer. Once inoculated, panels are placed into the instrument and continuously incubated at 35°C. The instrument tests panels every 20 minutes: on the hour; at 20 minutes past the hour; and again at 40 minutes past the hour up to 16 hours if necessary. Phoenix panels are read only by the instrument. Phoenix panels cannot be read manually.


    __________________________________________________ ________

    نبذة عن الجهاز :

    The BD Phoenix™ Automated Microbiology System is intended for the in vitro rapid identification (ID) of Gram Positive bacteria from pure culture belonging to the genera Staphylococcus, Enterococcus, and other Gram Positive cocci and Gram Positive bacilli. The BD Phoenix Automated Microbiology System is also intended for the quantitative determination of antimicrobial susceptibility by minimal inhibitory concentration (MIC) of most Gram Positive bacteria from pure culture belonging to the genera Staphylococcus and Enterococ

    __________________________________________________ ______________

    هذا الموقع عباره عن ملف فيه شرح وافي للجهاز و كل متعلقاته راح يفيدك مررره اضغط هنا

    و للاستزاده و مشاهدت تفاصيل الجهاز اضغط هنا