500 Semi-Auto Biochemistry Analzyer
1. Steady and reliable LED cold light source instead of Tungsten Halogen, lifetime is up to hundreds of thousand hours.
2. Unique graphic processing patent technology, assure excellent stability and reliability of the instrument.
3. High standard international universal power supply, making the instrument work all over the world.
4. Full-open program system, all kinds of reagents are available.
General introduction
Adopting international advanced LED cold light source part, using unique graphic processing technology and proprietary intellectual property rights computer software, the instrument has advantages of low consumption, long lifetime, steady and reliable characters. It is the first LED semi auto biochemistry analyzer in China, belonging to national patent product.
Features
(1) Adopt LED luminescence component with simple structure. Without brittle devices, such as bulb and filter, so there are scarcely any cost of usage and maintenance.
(2) Low consumption, low temperature, few malfunction, long lifetime and steady and reliable characters.
(3)Control and manage data through build-in micro-processor.
(4) High automated level, with many automated functions, such as: Auto wavelength transform, auto print, auto display, ect.
(5) Open programming, reagent free-choice.
(6) Testing method: End point, two-point, kinetics, multipoint scaling, immune turbidity, absorbance, sample blank, single and double wavelength.
(7) Dynamic realtime curve display, monitoring reagent invalidation, concentration overtop, over linearity in time.
(8) Auto storing QC within 31 days, display and print QC chart and statistics data.
(9) New type storage mode, permanently protect data from suddenly power off.
(10)High-capacity store sample test results \QC data and QC chart.
(11)Print item report and comprehensive sample report, store item list and every item program parameter.
Main specifications
1. Light source: LED-Cold Light Source
2. Wavelength range: 340-850nm
3. Absorbance range: -0.3~3.5ABS
4. Absorbance resolution: 0.001ABS(display) 0.0001ABS(inside)
5. Stability: ≤ 0.005Abs/20min
6. Cross contamination: ≤ 0.5%
7. Flowing colorimetric cell: 10mm 32ul
8. Temperature control: 25º C, 30º C, 37º C, room temperature
9. Once injection: 100~2000ul
10. Display: 240× 128 lattice LCD
11. Printer: Build-in thermal sensitive printer, the width of print paper is 110mm
12. Interface: Standard RS232 interface
************************************************
GF-D300 Semi-Auto Biochemistry Analyzer
1 Based on the Linux operating system, the presente in figures and diagrams contact surface, large screen real color liquid crystal display
2 Touch screen operation, English input
3 Adopt 32 bit high speed RISC processors, operating speed is up to 220, 000, 000 times per second.
4 Optimal Optical Performance
Adopt inported concave grating as dispersive element, adjust wavelength continuously, good optical performance, long life time.
5 Fire-new Biochemistry Management System
Based on the Linux operating system, the presente in figures and diagrams contact surface, large screen real color liquid crystal display
Touchscreen operation, English input, adopt 32 bit high speed RISC processors, operating speed is up to 220, 000, 000 times per second.
Build-in integrated biochemistry management software engine, can manage data and input patients material in English directly.
6 Comprehensive measuring method and computing mode
Kinetics, End Point (Linear\Non-linear), Two-point, Absorbance, Single Wavelength, Double wavelength, Sample Blank;
7 Perfect QC Method
With three different concentration QC test and multi-rule judgement function, auto statisitc and draw L-J QC chart, can query and print QC chart and QC data.
8 Powerful Database
Store over 200 item programme parameters, 500, 000 measuring data and over 2 years' three level QC data and QC chart, also can query and print at any time; With functions of data guide and educe.
Practical Functions
1. With many kinds of jurisdiction cascade protection function.
2. Colorized graphical interfaces, input information of doctor and patient with touchscreen of the instrument or mouse\keyboard, operation simple and direct-viewing.
3. Interface has real-time help and operation prompt functions.
4. Setup standard repeated measuring times, with auto repeated standard measuring and compute average value function.
5. Setup reference range according to different sex\age, more convenient to clinical reference.
6. Auto store\auto print, dynamically display response process curve.
Main Technical Parameters:
1 Light source: Halogen lamp
2 Wavelength Range: 280~1000 nm
3 Wavelength Accuracy: ± 1 nm
4 Range of absorbency: 0-3.0A
5 Cross Contamination: <1%
6 Colorimatric Cell: 10mm\32ul
7 Temperature Control: 25º C\30º C\37º C and Room Temperature
8 Temperature Accuracy: ± 0.1º C
9 Processor: Built-in high speed processor
10 Storage: Store over 200 test items and 500, 000 test results.
11 Display: High resolution colorized LCD display, dynamically display reaction curve.
12 Print: Build-in 110mm high speed thermal sensitive printer, also can connect outside printer.
13 Interface: Standard RS-232 interface\4 USB interfaces, Ethernet interface.
************************************************** **
GF-2280 Auto Biochemistry Analyzer
GF-2280 is a fashioned, quick, multi-function automatic biochemistry analyzer. Adopting foreign advanced technology, imported key parts, it's specially designed against the reality of all leveled hospitals, all the working procedures of instrument is controlled by computer, the rich software functions make the performance more superior, operation more easy.
Features
1. It can automatically optimize testing order, reduce waiting time, improve testing speed.
2. Automatic stirring and mixing, makes the mixture of sample and reagent more even, reaction more perfect.
3. Flexile and open reagent scheme, one reagent is available to many items.
4. Free set of calculation item of multi-item participation.
5. Completed quality-control scheme, different thickness of high, medium, low, support L-J and X-B quality control.
6. Dynamic real-time reaction curve monitors the disabled reagent timely, prompt too high thickness and make automatic dilution of sample.
7. Insert emergency at any time, and start emergency testing at fist time.
8. In running, the graphic guide-view system of reagent and sample tray makes it more easy to provide the user to look over and master testing information.
9. Strong database storage technology, hundreds of storage of result, with no influence to running speed.
10. Complete setup to reference range as different sex and age provides convenience to clinical reference.
Main technical index:
1. Wavelength: 8 filters, 340, 380, 405, 492, 510, 546, 578, 630nm, or match as user's demand.
2. Tempearature control: 25º C, 30º C, 37º C± 0.1º C
3. Analysis method: End point, dynamic, fixed time, sample blank, reagent blank, absorbency, double-wavelength, etc.
4. Testing speed: 200 samples/hour.
5. Reagent capacity: 3 reagent tray, 17 reagents/tray, 51 samples for one time ( including standard).
6. Crossed contamination: ≤ 1%.
7. Computer: Pentium computer chip.
8. Monitor: Big-screen color monitor.
9. Printer: Outside high resolution printer.
10. Keyboard: Standard computer keyboard.
11. Exterior interface: Bidirectional RS-232.
Complete quality control solution, provides pre-set value, optimal calculation of quality control, daily calculation of quality control data, etc, meet all the routine demands.
Based on the system of window XP, In running, graphic guide-view system of reagent and sample tray, provide the user convenience to look over and master the test of item, and display testing graphs real-time.
Strong data analysis and monitoring capacity, automatically judges the parameters of reagent and samples, completely masters the test analysis.
Seeing is the result, the final report can be looked over before printing, including multiple optical report formats.
Human-based program edition setting makes it easy to input information for operators, and quicken the issuing time of inspection report.
************************************************** ******
Product Description
Measurement System: 8-Channel optical system
Measurement Range: 0.000-4.000ABS
Photometric Accuracy: ± 1% or ± 0.001ABS
Repeatability: <± 0.3%
Stability: <0.002ABS
Linearity: <± 0.5%
Reading Speed: <5secs/96holes(single wavelength)
<7secs/96holes(double wavelength)
Filters: Standard: 7 filters (405, 450, 492, 630 nm)
Or other wavelength on request.
Packing Details: 680mm*530mm*600mm
N. W. 12kgs G. W. 15kgs
************************************************** *****
Clinical Laboratory Analyzer YSTE0102
Medical Biochemical Analyzer (2)
Up to 250 test items
6 wavelengths optic system avoiding outer disturbance
(Wavelength: 340-700nm)
Open reagent
Technical Specification
Method
Kinetic, End-point, Linearity end-point, Non-linearity end-point, Absorbency, Sample blank, Multi-standards, Velocity, Calculation, Fixed Time, bichromatic etc.
Wavelength Range
6 wavelengths optic system avoiding outer disturbance,
Wavelength range: 340 nm-700 nm;
Filter Wavelengths: 340, 405, 492, 510, 546, 578, 630nm + 2 free position
Wavelength precision: ± 2nm
Quality Control
Quality control for all tests,
Statistic and print quality control parameters automatically with QC curves;
Program: Add or delete test items easily according to the condition, modify the test parameters;
Display Dynamic curves at real time, visually react the process;
Dormant automatically for the lamp to prolong it's lifespan;
Input 8 standard curves at most in testing with multi-standard method;
Open reagent;
Specifications
Test items: ≥ 250
Flow cell: Quartz flow cell 32UL
With both shipping and cuvette system
Lamp: PHILIP 6V 10W
Measurement range: 0~2.5ABS
Resolution: 0.001 ABS(display), 0.0001 ABS (calculation)
Temperature control: Peltier 37° C, 30° C, 25° C± 0.1° C
Repeatability: <1%
Data Communication
RS-232 serial port
Power Reuquirement
AC 220V± 15%, 50-60Hz, 100W
Output
Inner thermal printer
External parallel printer
Display
240*128 LCD
Interface
RS-232C serial port
Dimension: 330mm*355mm*126mm (L*W*H)
Weight: 8Kg
************************************************** *******
Product Description
Features:
Advanced medical image fusion technology, plane stream technology, automatic phase contrast microscopic examination, and intelligent analysis of machine visual technology.
Effective pressure bubble monitoring system does real-time monitoring on the complete working process. High pressure alarm, low pressure alarm, bubble alarm, system error alarm, and out of reagent alarm are available.
Fully automated and continuous orbital sampling of 10-tube specimen holder. Just place the specimen holder and press Enter, and the device will do continuous examination based on 60 specimens per lot. Testing speed: 80-120 specimens per hour.
Available for Inserting specimen at any time, and no centrifuge needed. The device does mass and fast scanning on the specimens and avoid undetected during clinical application even without centrifuge.
Double-pipette / double-channel detection to increase detection speed. Automatically clean the inner & outer of the sampling pipettes to avoid mixing up of the urine samples.
Two-way communication, connectable with hospital HIS, LIS network. Bar code identification, and special multi-media keyboard.
Position for emergency specimen: Automatically detect and reset the emergency specimen without manual push-and-pull.
WINDOWS XP platform and dual-core computer processing system. Conduct patient information processing and image identification system processing at the same time
Low costs, maximum profits.
************************************************** *******
Specifications for Biochemistry Analyzer (D500):
1. Wavelength: 340, 405, 505, 540, 580, 620, 690nm
2. Wavelength accuracy: ± 3nm
3. Stray light: ≤0.5% (or Absorbency≥ 2.3)
4. Stability: ≤0.005Abs/20min
5. Temperature control: 37º C, or 30º C, or 25º C or room temperature
6. Absorbency linearity:
a Absorbency 0.2-≤0.5≤± 5%
b Absorbency ≥ 0.5-≤1.0≤± 4%
c Absorbency ≥ 1.0-≤1.8≤± 2%
7. Repeatability: CV≤1.0%
8. Cross contamination: ≤0.5%
9. Clinical items accuracy
Clinical items accuracy
Item Analysis Method Concentration Range coefficient of variation
ALT Kinetics (60-70)u/L ≤5%
UREA Two points (9.00-10.00)mmol/L ≤3.5%
TP End point (60.0-65.0)g/L ≤2.5%
10. Testing method:
(1) End point
(2) Standard curve
(3) Factor input
(4) Two-point (fixed time)
(5) Kinetic
(6) Double wavelength
(7) Absorbance
(8) Sample blank
(9) Reagent blank
11. Opening reagents and choose freely.
12. Item coefficient: store testing results of 3000 samples, query and print them at any time; 70 fixed items, 100 programming items.
13. Open programming
14. standard RS232 interface
15. Keyboard: thin-film light touch keyboard
16. Display mode: big screen LCD
17. Printer: Build-in thermal sensitive printer, the width of print paper is 110nm
18. Environmental temperature: 10º C-30º C
19. Relative environmental humidity: ≤80%
20. Sample volume: 1-50ul (according to demand of the reagent)
21. Colorimetric cell: quartz flowing, 32ul capacity, 10mm path
22. Power supply: 86V-264V 50Hz/60Hz
23. Dimension(mm): 440x410x195
24. Weight: 8kg
************************************************** ****
Automatic biochemical analyzer (SUNMATIK-6008)
Sunostik Medical Technology Co., Ltd.
1, Fully automated, random access chemistry analyzer;
2, Samll volume, compact conformation, multi-function;
3, Throughput: 150 tests/hour;
4, 56 reagent positions, 28 sample positions;
5, 24-hour cooling;
6, Reagent pre-heating function;
7, Emergency samples tested preferentially intelligent probe can do liquid level detection and have collision protection function;
8, Cuvette auto-washing, and cuvette blank detection;
9, Multitask software for easy operatio
************************************************** ****
Automatic biochemical analyzer (SUNMATIK-6020)
Sunostik Medical Technology Co., Ltd.
1, Fully automated, random access chemistry analyzer;
2, Throughput: 200 tests/hour, up to 280t/hour with ISE;
3, Unique optical system design;
4, Sigle-wavelength, dual-wavelength and multi-wavelength measurement supported;
5, Plastic cuvette, with excellent UV penetrability, durable and economic;
6, Independent mixer, fuctions immediately after the samples and reagent pipetted in 8-step auto-washing, prevent cross contamination;
7, Long life span ceramic piston pump, durable;
8, Multitask software for eay operation.
************************************************** *****
FAITH-1020 is a random access automatic biochemistry analyzer. It adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical guideline of patient.
1. Test speed 160 tests/hour(invariable speed)
2. Methodology End-point, Kinetic, Fixed time;
3. Sample Tray 58 non-fixed positions for various samples
4. Reagent Tray 49 positions for reagent bottles
5. Cuvette 120 reaction bottles; Optical length: 6mm
6. Reaction volume 180-500UL
7. Compatible reagent: Supports different reagents from different countries
8. Sample volume 2 to 50UL
9. Reagent volume R1 25-300UL; R2 10-150UL
10. Reaction volume 180-500UL
11. Reaction time about 10 minutes
12. Calibration methods Linear and non-linear
13. Wavelength 340, 405, 510, 546, 578, 600, 660, 700...
14. System function 24 hour non-stop working, Support STATtests; 2-wavelength photometer
15. Lamp 12v20w, 8 photodiodes
16. Power 110/220v
17. Software Multinational language, use-friendly interface by Windows.
************************************************** ******
Faith-1000 is a random access automatic biochemistry analyzer. It
adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical index of patient.
Main specifications:
1. Test speed: 200 tests/hour
2. Assay types: End-point assay, rate assay, fixed-point assay...
3. Assay items: 45 items once time
4. Cuvette: 120 reaction bottles; Light path length: 6mm
5. Total reaction volume: 180UL minimum
6. Sample volume: 2 to 50 microliters
7. Reagent volume: R1 25UL-300UL; R2 10UL-150UL
8. Reaction time: About 10 minutes
9. Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm
10. Quality control: 6 types per test item
11. Dimensions: 96cm*71cm*54cm
Loading sample system
1. The loading apparatus(syringe) is imported from German microsyring which is assured the accuracy of minimum sample.
2. The probe needle connected the high-precision syringe is washed inside and outside by pressure water (warm or normal temperature) or cleaning liquid which are pumped.
Liquid level sense system
1. The probe has the coat of tfl can reduce across-polluter evidently.
2. The system solve the problem of reaction cups thoroughly by the particular design which got rid of washing system.
3. The urgent sample can be tested preferentially at any time.
Washing station
1.8 washing needles connected with 4 pumps.
2. High pressure water or cleaning liquid
3. Synchronous and in time with the test.
Cold storage and calefaction system
1. The sample and reagent can be hold longtime stabilization by semiconductor refrigeration.
2. The analyzer can lodge 60 sample cups and 45 reagent bottles.
3. The intelligent temperature system will heat up the reaction solution to the appropriate reaction temperature
Optical system
1. The system include light filter, optical fiber, 120 reaction bottles and photoelectric receiver which are imported.
2. Reaction time is about 10 minutes.
3. The point of reading can be set freely.
Operation system
1. The software use the language of Chinese or English.
2. The function include testing calculations, sample blank correction, correlative, panic, dynamic and repeat run range judgements; Reagent absorbance and reaction mixture absorbance check; Abnormal value, pending and repeat run lists; Report format printing.
Complete customer service
1. We provide fine products and all-sided service for our customers.
2. We have highly trained customer service and professional technical support staff to slove any possible problems customers may have.
3. We are willing to establish good business relations with companies all over the world.
************************************************** ********
Stream line design, nice appearance.
Self calibration and trouble alarm function.
Absolutely open system: Both of programming and reagent.
Warning tone for finished sipping and any other ready function.
Function sketches on main menu, the software is simplicity, easy and fast operation.
Real time curve monitoring enhances the reliability of result.
Memory for 100 programs and 20000 test results, results tracking by date.
On-broad Quality control, control results available either memory or display.
Technical Parameters:
Measuring Mode: Kinetics, End point, Fixed time, Differential, Absorbance, Multi-standard.
Light source: 6v/10w Halogen Lamp, life Span>3000 hours.
Standard filter: 340nm, 405nm, 505nm, 546nm, 578nm, 620nm, 670nm and one free position.
Band width: ≤ 8nm.
Linearity range: 0.000-3.000ABS.
Aspiration volume: 200-1400UL.
Flow cell: 32UL, Optical diameter: 1cm.
Cross contamination rate: ≤ 1%.
Temperature control: 25º C, 30º C, 37º C, ± 0.1º C and be controlled by peliter.
Language: English or any language on request.
Output: Built-in printer, RS232 for additional PC.
Display: 240*128LCD.
Power supply: AC220V± 10%, 50/60Hz.
Dimension: 430(L)mm× 320(W)mm× 220(H)mm.
Net weight: 9.0kg.
************************************************** ******
Type: Fully automated, desktop, random access, clinical chemistry analyzer
Throughput: 130 tests / hour, up to 200 tests / hour with ISE (optional)
Test Mode: End point, Fixed time (two point), Kinetics (velocity), Immuno assays; Monochromatic, Bi-chromatic & Multi-chromatic; Linearity & Nonlinearity, Single / Dual Reagents, Monochromatic / Bi-chromatic testing
Test Range: Clinical Biochemistry, Specific protein, ISE, Therapeutic medicine, Drug abuse, Urine/ Cerebrospinal fluid
Sample tray: 28 sample positions, any position can be aligned as STAT which can be inserted at any time during the routine examination
Sample tubes: Sample cup, Vacuum blood collection tube, plastic tubes are all available
Sample volume: 2µ L~35µ L, programmed in 0.1µ L step
Reagent tray: 56 reagent positions for R1 and R2
Refrigeration: 24 hours non-stop cooling with Peltier element maintaining temperature 4~15º C; Controlled by a separately switch
Reagent bottle: 15ml, 35ml and 40ml; Slope bottom design
Reagent volume: 150µ L ~300µ L, programmed in 1µ L step, reagent blank can be deducted automatically when testing
Sample & Reagent Probe: Integrated multi-function reagent needle with liquid surface detection, collision protection, reagent pre-heating function, reagent residual volume monitoring and alarming function
Probe Cleaning: Inner and outer wall auto washing with warm water, carry over < 0.1%
Syringe: American imported, long-life span, high-accuracy, durable and maintenance free
Optional item: Bar code reader
Reaction tray: 48 reaction cuvettes, 6mm optical path, plastic cuvette, semi-permanent
Reaction volume: 150µ L ~300µ L
Reaction time: About 10 minutes
Temperature: 37º C, fluctuation + 0.1º C
Light source: Halogen lamp, 6V/10W, life span ≥ 3000 hours
Wavelength: 340nm, 405nm, 450nm, 492nm, 505nm, 546nm, 578nm, 620nm, 670nm, 700nm
Absorbance range: 0.000 ABS ~3.000 ABS
Resolution: 0.001ABS
Calibration & Quality Control
Calibration mode: Linear (one-point, two-point and multi-point), Logit-Log4P, Logit-Log5P, Spline curve, Exponential Function, Polynomial, Parabola
QC rules: Westgard Multi-rule, Cumulative Sum Check, Twin Plot, 3 concentration levels QC
QC mode: Real time, Intra day & Inter day QC
************************************************** ******
Stream line design, nice appearance
More than 70 items including routine and STAT parameters
Reagent system open
Two reading modes: Cuvetle & Flow cell
RS232 interface, intelligent software, 1200testing results in memory can be printed
Built-in thermo printer
Technical Parameters:
Light source: 12v/20w Halogen Lamp, life Span>2000 hours
Standard filter: 340nm, 405nm, 505nm, 546nm, 578nm, 620nm, 670nm and one free position
Band width: ≤ 8nm
Linearity range: 0.000-3.000ABS
Aspiration volume: 200-1400UL
Flow cell: 30UL, Optical diameter: 1cm
Cross contamination rate: ≤ 2%
Operational temperature: 10~40º C
Temperature control: 25º C, 30º C, 37º C, ± 0.1º C and be controlled by peliter
Measuring Mode: Kinetics, End point, Fixed time, Differential, Absorbance, Multi-standard, Double wavelength
Display: 240*128LCD
QC: Statistically analyzed of QC DATA; QC chart can be displayed and memorized Standard RS-232 interface
RH: ≤ 85%
Power supply: AC220V± 10%, 50Hz± 2%
Dimension: 460(L)mm× 380(W)mm× 220(H)mm
Net weight: 14kg
************************************************** *******
Main Specifications for GF-3000 21-Phase Trisection Automatic Blood Cell/ Hematology Analyzer
Working principle: Resistance calculation, cyanogen ferrihemoglobin method.
Test parameter: Leucocyte three categories, 21-parameter
Sample dosage: Automatic pre-diluted peripheral blood 20UL, blood coagulation 13UL.
Working mode: Double-passage measure+ independent hemoglobin test system
Aperture of micro-pore WBC 100um, RBC/PLT 70um
Working speed: The time from sampling to test is less than 1 min. It can work for the whole day with dormancy function.
Result storage: Automatically store 1250 reports containing results of 3 histograms
Quality inspection manner: X-B, L-J graphic
Signing manner: Manual signing and automatic signing
Reagent dosage: Diluent 25ml/sample
Hemolytic agent 0.5ml or 0.36ml/sample
Rinse solution: 6ml/sample
Index
Parameter
Linearity extension
Precision (CV value)
Leucocyte number
WBC(109 /L)
0.00-99.9
2.0% (5.0-15.0x109 /L)
Red blood cell number
RBC(1012 /L)
0.00-9.99
1.5% (3.5-6.0x1012/L)
Hemoglobin
HGB (g/L)
0.0-300.0
1.5% (110-180g/L)
Average red blood cell cubage
MCV (fL)
40.0-150.0
0.5% (80.0-110.0Fl)
Haematoblast number
PLT (109 /L)
0.0-999.0
4.0%(100-500x109 /L)
Across pollution WBC, RBC, HGB≤ 0.5%, PLT≤ 1%
Monitor 640x480 resolution, large screen 8 colored LCD
Input and output entrance, one parallel printer port, one RS232 port (network function), one RS232 port (coder available for sample number listing), one keyboard port
Print report, efficient heat sensitive printing, paper width 5.0cm, adopting Epson stylus printer, plug-and-play, the digital management software is also adoptable.
Working environment: Temperature 15º C-35º C, humidity 10%-90%, used in high altitude.
Power supply: 220V± 15%, 50Hz ± 2%
Dimensions: 460 mm (H) x 390 mm (W) x 390 mm (D)
Weight 25kg
************************************************** *********
Faith-3000 is a random access automatic biochemistry analyzer. It adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical indicates of patient.
Main specifications:
1. Test speed: 300 tests/hour
2. Assay types: End-point assay, rate assay, fixed-point assay...
3. Assay items: 45 items each time
4. Cuvette: 120 reaction bottles; Light path length: 6mm
5. Total reaction volume: 180UL minimum
6. Sample volume: 2 to 50 microliters
7. Reagent volume: R1 25UL-300UL; R2 10UL-150UL
8. Reaction time: About 10 minutes
9. Wavelength: 340, 380, 405, 450, 510, 546, 578, 600, 660, 700, 800nm
10. Quality control: 6 types per test item
Loading sample system
1. The loading apparatus(syringe) is imported from German microsyring which is assured the accuracy of minimum sample.
2. The probe needle connected the high-precision syringe is washed inside and outside by pressure water (warm or normal temperature) or cleaning liquid which are pumped.
Liquid level sense system
1. The probe has the coat of tfl can reduce across-polluter evidently.
2. The system solve the problem of reaction cups thoroughly by the particular design which got rid of washing system.
3. The urgent sample can be tested preferentially at any time.
Separate whisk arm
1. Mix the reaction solution to urge reacting adequately
2. Separate needle avoids across-polluter.
Washing station
1.8 washing needles connected with 4 pumps.
2. High pressure water or cleaning liquid
3. Synchronous and in time with the test.
Cold storage and calefaction system
1. The sample and reagent can be hold longtime stabilization by semiconductor (8 degrees under the rt) or compressor refrigeration. 2. The analyzer can lodge 60 sample cups and 45 reagent bottles.
3. The intelligent temperature system will heat up the reaction solution to the appropriate reaction temperature
Optical system
1. The system include light filter, optical fiber, 120 reaction bottles and photoelectric receiver which are imported.
2. Reaction time is about 10 minutes.
3. The point of reading can be set freely.
Operation system
1. The software use the language of Chinese or English.
2. The function include testing calculations, sample blank correction, correlative, panic, dynamic and repeat run range judgements; Reagent absorbance and reaction mixture absorbance check; Abnormal value, pending and repeat run lists; Report format printing.
Complete customer service
1. We provide fine products and all-sided service for our customers.
2. We have highly trained customer service and professional technical support staff to slove any possible problems customers may have.
3. We are willing to establish good business relations with companies all over the world.
اقدم اليكم هذا الملف عسى الله ان ينفعنا واياكم
ولاتنسونا بدعواتكم الطيبه
مع خالـــــــــــــــــــــــــــــــص تحياتي
السنوسي احموده احمد
اخصائي تحاليل طبيه
سبها /ليبيا
sonuci_2010 libya-sebha
------------------------------------------------------------------------------
500 Semi-Auto Biochemistry Analzyer
1. Steady and reliable LED cold light source instead of Tungsten Halogen, lifetime is up to hundreds of thousand hours.
2. Unique graphic processing patent technology, assure excellent stability and reliability of the instrument.
3. High standard international universal power supply, making the instrument work all over the world.
4. Full-open program system, all kinds of reagents are available.
General introduction
Adopting international advanced LED cold light source part, using unique graphic processing technology and proprietary intellectual property rights computer software, the instrument has advantages of low consumption, long lifetime, steady and reliable characters. It is the first LED semi auto biochemistry analyzer in China, belonging to national patent product.
Features
(1) Adopt LED luminescence component with simple structure. Without brittle devices, such as bulb and filter, so there are scarcely any cost of usage and maintenance.
(2) Low consumption, low temperature, few malfunction, long lifetime and steady and reliable characters.
(3)Control and manage data through build-in micro-processor.
(4) High automated level, with many automated functions, such as: Auto wavelength transform, auto print, auto display, ect.
(5) Open programming, reagent free-choice.
(6) Testing method: End point, two-point, kinetics, multipoint scaling, immune turbidity, absorbance, sample blank, single and double wavelength.
(7) Dynamic realtime curve display, monitoring reagent invalidation, concentration overtop, over linearity in time.
(8) Auto storing QC within 31 days, display and print QC chart and statistics data.
(9) New type storage mode, permanently protect data from suddenly power off.
(10)High-capacity store sample test results \QC data and QC chart.
(11)Print item report and comprehensive sample report, store item list and every item program parameter.
Main specifications
1. Light source: LED-Cold Light Source
2. Wavelength range: 340-850nm
3. Absorbance range: -0.3~3.5ABS
4. Absorbance resolution: 0.001ABS(display) 0.0001ABS(inside)
5. Stability: ≤ 0.005Abs/20min
6. Cross contamination: ≤ 0.5%
7. Flowing colorimetric cell: 10mm 32ul
8. Temperature control: 25º C, 30º C, 37º C, room temperature
9. Once injection: 100~2000ul
10. Display: 240× 128 lattice LCD
11. Printer: Build-in thermal sensitive printer, the width of print paper is 110mm
12. Interface: Standard RS232 interface
************************************************
GF-D300 Semi-Auto Biochemistry Analyzer
1 Based on the Linux operating system, the presente in figures and diagrams contact surface, large screen real color liquid crystal display
2 Touch screen operation, English input
3 Adopt 32 bit high speed RISC processors, operating speed is up to 220, 000, 000 times per second.
4 Optimal Optical Performance
Adopt inported concave grating as dispersive element, adjust wavelength continuously, good optical performance, long life time.
5 Fire-new Biochemistry Management System
Based on the Linux operating system, the presente in figures and diagrams contact surface, large screen real color liquid crystal display
Touchscreen operation, English input, adopt 32 bit high speed RISC processors, operating speed is up to 220, 000, 000 times per second.
Build-in integrated biochemistry management software engine, can manage data and input patients material in English directly.
6 Comprehensive measuring method and computing mode
Kinetics, End Point (Linear\Non-linear), Two-point, Absorbance, Single Wavelength, Double wavelength, Sample Blank;
7 Perfect QC Method
With three different concentration QC test and multi-rule judgement function, auto statisitc and draw L-J QC chart, can query and print QC chart and QC data.
8 Powerful Database
Store over 200 item programme parameters, 500, 000 measuring data and over 2 years' three level QC data and QC chart, also can query and print at any time; With functions of data guide and educe.
Practical Functions
1. With many kinds of jurisdiction cascade protection function.
2. Colorized graphical interfaces, input information of doctor and patient with touchscreen of the instrument or mouse\keyboard, operation simple and direct-viewing.
3. Interface has real-time help and operation prompt functions.
4. Setup standard repeated measuring times, with auto repeated standard measuring and compute average value function.
5. Setup reference range according to different sex\age, more convenient to clinical reference.
6. Auto store\auto print, dynamically display response process curve.
Main Technical Parameters:
1 Light source: Halogen lamp
2 Wavelength Range: 280~1000 nm
3 Wavelength Accuracy: ± 1 nm
4 Range of absorbency: 0-3.0A
5 Cross Contamination: <1%
6 Colorimatric Cell: 10mm\32ul
7 Temperature Control: 25º C\30º C\37º C and Room Temperature
8 Temperature Accuracy: ± 0.1º C
9 Processor: Built-in high speed processor
10 Storage: Store over 200 test items and 500, 000 test results.
11 Display: High resolution colorized LCD display, dynamically display reaction curve.
12 Print: Build-in 110mm high speed thermal sensitive printer, also can connect outside printer.
13 Interface: Standard RS-232 interface\4 USB interfaces, Ethernet interface.
************************************************** **
GF-2280 Auto Biochemistry Analyzer
GF-2280 is a fashioned, quick, multi-function automatic biochemistry analyzer. Adopting foreign advanced technology, imported key parts, it's specially designed against the reality of all leveled hospitals, all the working procedures of instrument is controlled by computer, the rich software functions make the performance more superior, operation more easy.
Features
1. It can automatically optimize testing order, reduce waiting time, improve testing speed.
2. Automatic stirring and mixing, makes the mixture of sample and reagent more even, reaction more perfect.
3. Flexile and open reagent scheme, one reagent is available to many items.
4. Free set of calculation item of multi-item participation.
5. Completed quality-control scheme, different thickness of high, medium, low, support L-J and X-B quality control.
6. Dynamic real-time reaction curve monitors the disabled reagent timely, prompt too high thickness and make automatic dilution of sample.
7. Insert emergency at any time, and start emergency testing at fist time.
8. In running, the graphic guide-view system of reagent and sample tray makes it more easy to provide the user to look over and master testing information.
9. Strong database storage technology, hundreds of storage of result, with no influence to running speed.
10. Complete setup to reference range as different sex and age provides convenience to clinical reference.
Main technical index:
1. Wavelength: 8 filters, 340, 380, 405, 492, 510, 546, 578, 630nm, or match as user's demand.
2. Tempearature control: 25º C, 30º C, 37º C± 0.1º C
3. Analysis method: End point, dynamic, fixed time, sample blank, reagent blank, absorbency, double-wavelength, etc.
4. Testing speed: 200 samples/hour.
5. Reagent capacity: 3 reagent tray, 17 reagents/tray, 51 samples for one time ( including standard).
6. Crossed contamination: ≤ 1%.
7. Computer: Pentium computer chip.
8. Monitor: Big-screen color monitor.
9. Printer: Outside high resolution printer.
10. Keyboard: Standard computer keyboard.
11. Exterior interface: Bidirectional RS-232.
Complete quality control solution, provides pre-set value, optimal calculation of quality control, daily calculation of quality control data, etc, meet all the routine demands.
Based on the system of window XP, In running, graphic guide-view system of reagent and sample tray, provide the user convenience to look over and master the test of item, and display testing graphs real-time.
Strong data analysis and monitoring capacity, automatically judges the parameters of reagent and samples, completely masters the test analysis.
Seeing is the result, the final report can be looked over before printing, including multiple optical report formats.
Human-based program edition setting makes it easy to input information for operators, and quicken the issuing time of inspection report.
************************************************** ******
Product Description
Measurement System: 8-Channel optical system
Measurement Range: 0.000-4.000ABS
Photometric Accuracy: ± 1% or ± 0.001ABS
Repeatability: <± 0.3%
Stability: <0.002ABS
Linearity: <± 0.5%
Reading Speed: <5secs/96holes(single wavelength)
<7secs/96holes(double wavelength)
Filters: Standard: 7 filters (405, 450, 492, 630 nm)
Or other wavelength on request.
Packing Details: 680mm*530mm*600mm
N. W. 12kgs G. W. 15kgs
************************************************** *****
Clinical Laboratory Analyzer YSTE0102
Medical Biochemical Analyzer (2)
Up to 250 test items
6 wavelengths optic system avoiding outer disturbance
(Wavelength: 340-700nm)
Open reagent
Technical Specification
Method
Kinetic, End-point, Linearity end-point, Non-linearity end-point, Absorbency, Sample blank, Multi-standards, Velocity, Calculation, Fixed Time, bichromatic etc.
Wavelength Range
6 wavelengths optic system avoiding outer disturbance,
Wavelength range: 340 nm-700 nm;
Filter Wavelengths: 340, 405, 492, 510, 546, 578, 630nm + 2 free position
Wavelength precision: ± 2nm
Quality Control
Quality control for all tests,
Statistic and print quality control parameters automatically with QC curves;
Program: Add or delete test items easily according to the condition, modify the test parameters;
Display Dynamic curves at real time, visually react the process;
Dormant automatically for the lamp to prolong it's lifespan;
Input 8 standard curves at most in testing with multi-standard method;
Open reagent;
Specifications
Test items: ≥ 250
Flow cell: Quartz flow cell 32UL
With both shipping and cuvette system
Lamp: PHILIP 6V 10W
Measurement range: 0~2.5ABS
Resolution: 0.001 ABS(display), 0.0001 ABS (calculation)
Temperature control: Peltier 37° C, 30° C, 25° C± 0.1° C
Repeatability: <1%
Data Communication
RS-232 serial port
Power Reuquirement
AC 220V± 15%, 50-60Hz, 100W
Output
Inner thermal printer
External parallel printer
Display
240*128 LCD
Interface
RS-232C serial port
Dimension: 330mm*355mm*126mm (L*W*H)
Weight: 8Kg
************************************************** *******
Product Description
Features:
Advanced medical image fusion technology, plane stream technology, automatic phase contrast microscopic examination, and intelligent analysis of machine visual technology.
Effective pressure bubble monitoring system does real-time monitoring on the complete working process. High pressure alarm, low pressure alarm, bubble alarm, system error alarm, and out of reagent alarm are available.
Fully automated and continuous orbital sampling of 10-tube specimen holder. Just place the specimen holder and press Enter, and the device will do continuous examination based on 60 specimens per lot. Testing speed: 80-120 specimens per hour.
Available for Inserting specimen at any time, and no centrifuge needed. The device does mass and fast scanning on the specimens and avoid undetected during clinical application even without centrifuge.
Double-pipette / double-channel detection to increase detection speed. Automatically clean the inner & outer of the sampling pipettes to avoid mixing up of the urine samples.
Two-way communication, connectable with hospital HIS, LIS network. Bar code identification, and special multi-media keyboard.
Position for emergency specimen: Automatically detect and reset the emergency specimen without manual push-and-pull.
WINDOWS XP platform and dual-core computer processing system. Conduct patient information processing and image identification system processing at the same time
Low costs, maximum profits.
************************************************** *******
Specifications for Biochemistry Analyzer (D500):
1. Wavelength: 340, 405, 505, 540, 580, 620, 690nm
2. Wavelength accuracy: ± 3nm
3. Stray light: ≤0.5% (or Absorbency≥ 2.3)
4. Stability: ≤0.005Abs/20min
5. Temperature control: 37º C, or 30º C, or 25º C or room temperature
6. Absorbency linearity:
a Absorbency 0.2-≤0.5≤± 5%
b Absorbency ≥ 0.5-≤1.0≤± 4%
c Absorbency ≥ 1.0-≤1.8≤± 2%
7. Repeatability: CV≤1.0%
8. Cross contamination: ≤0.5%
9. Clinical items accuracy
Clinical items accuracy
Item Analysis Method Concentration Range coefficient of variation
ALT Kinetics (60-70)u/L ≤5%
UREA Two points (9.00-10.00)mmol/L ≤3.5%
TP End point (60.0-65.0)g/L ≤2.5%
10. Testing method:
(1) End point
(2) Standard curve
(3) Factor input
(4) Two-point (fixed time)
(5) Kinetic
(6) Double wavelength
(7) Absorbance
(8) Sample blank
(9) Reagent blank
11. Opening reagents and choose freely.
12. Item coefficient: store testing results of 3000 samples, query and print them at any time; 70 fixed items, 100 programming items.
13. Open programming
14. standard RS232 interface
15. Keyboard: thin-film light touch keyboard
16. Display mode: big screen LCD
17. Printer: Build-in thermal sensitive printer, the width of print paper is 110nm
18. Environmental temperature: 10º C-30º C
19. Relative environmental humidity: ≤80%
20. Sample volume: 1-50ul (according to demand of the reagent)
21. Colorimetric cell: quartz flowing, 32ul capacity, 10mm path
22. Power supply: 86V-264V 50Hz/60Hz
23. Dimension(mm): 440x410x195
24. Weight: 8kg
************************************************** ****
Automatic biochemical analyzer (SUNMATIK-6008)
Sunostik Medical Technology Co., Ltd.
1, Fully automated, random access chemistry analyzer;
2, Samll volume, compact conformation, multi-function;
3, Throughput: 150 tests/hour;
4, 56 reagent positions, 28 sample positions;
5, 24-hour cooling;
6, Reagent pre-heating function;
7, Emergency samples tested preferentially intelligent probe can do liquid level detection and have collision protection function;
8, Cuvette auto-washing, and cuvette blank detection;
9, Multitask software for easy operatio
************************************************** ****
Automatic biochemical analyzer (SUNMATIK-6020)
Sunostik Medical Technology Co., Ltd.
1, Fully automated, random access chemistry analyzer;
2, Throughput: 200 tests/hour, up to 280t/hour with ISE;
3, Unique optical system design;
4, Sigle-wavelength, dual-wavelength and multi-wavelength measurement supported;
5, Plastic cuvette, with excellent UV penetrability, durable and economic;
6, Independent mixer, fuctions immediately after the samples and reagent pipetted in 8-step auto-washing, prevent cross contamination;
7, Long life span ceramic piston pump, durable;
8, Multitask software for eay operation.
************************************************** *****
FAITH-1020 is a random access automatic biochemistry analyzer. It adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical guideline of patient.
1. Test speed 160 tests/hour(invariable speed)
2. Methodology End-point, Kinetic, Fixed time;
3. Sample Tray 58 non-fixed positions for various samples
4. Reagent Tray 49 positions for reagent bottles
5. Cuvette 120 reaction bottles; Optical length: 6mm
6. Reaction volume 180-500UL
7. Compatible reagent: Supports different reagents from different countries
8. Sample volume 2 to 50UL
9. Reagent volume R1 25-300UL; R2 10-150UL
10. Reaction volume 180-500UL
11. Reaction time about 10 minutes
12. Calibration methods Linear and non-linear
13. Wavelength 340, 405, 510, 546, 578, 600, 660, 700...
14. System function 24 hour non-stop working, Support STATtests; 2-wavelength photometer
15. Lamp 12v20w, 8 photodiodes
16. Power 110/220v
17. Software Multinational language, use-friendly interface by Windows.
************************************************** ******
Faith-1000 is a random access automatic biochemistry analyzer. It
adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical index of patient.
Main specifications:
1. Test speed: 200 tests/hour
2. Assay types: End-point assay, rate assay, fixed-point assay...
3. Assay items: 45 items once time
4. Cuvette: 120 reaction bottles; Light path length: 6mm
5. Total reaction volume: 180UL minimum
6. Sample volume: 2 to 50 microliters
7. Reagent volume: R1 25UL-300UL; R2 10UL-150UL
8. Reaction time: About 10 minutes
9. Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm
10. Quality control: 6 types per test item
11. Dimensions: 96cm*71cm*54cm
Loading sample system
1. The loading apparatus(syringe) is imported from German microsyring which is assured the accuracy of minimum sample.
2. The probe needle connected the high-precision syringe is washed inside and outside by pressure water (warm or normal temperature) or cleaning liquid which are pumped.
Liquid level sense system
1. The probe has the coat of tfl can reduce across-polluter evidently.
2. The system solve the problem of reaction cups thoroughly by the particular design which got rid of washing system.
3. The urgent sample can be tested preferentially at any time.
Washing station
1.8 washing needles connected with 4 pumps.
2. High pressure water or cleaning liquid
3. Synchronous and in time with the test.
Cold storage and calefaction system
1. The sample and reagent can be hold longtime stabilization by semiconductor refrigeration.
2. The analyzer can lodge 60 sample cups and 45 reagent bottles.
3. The intelligent temperature system will heat up the reaction solution to the appropriate reaction temperature
Optical system
1. The system include light filter, optical fiber, 120 reaction bottles and photoelectric receiver which are imported.
2. Reaction time is about 10 minutes.
3. The point of reading can be set freely.
Operation system
1. The software use the language of Chinese or English.
2. The function include testing calculations, sample blank correction, correlative, panic, dynamic and repeat run range judgements; Reagent absorbance and reaction mixture absorbance check; Abnormal value, pending and repeat run lists; Report format printing.
Complete customer service
1. We provide fine products and all-sided service for our customers.
2. We have highly trained customer service and professional technical support staff to slove any possible problems customers may have.
3. We are willing to establish good business relations with companies all over the world.
************************************************** ********
Stream line design, nice appearance.
Self calibration and trouble alarm function.
Absolutely open system: Both of programming and reagent.
Warning tone for finished sipping and any other ready function.
Function sketches on main menu, the software is simplicity, easy and fast operation.
Real time curve monitoring enhances the reliability of result.
Memory for 100 programs and 20000 test results, results tracking by date.
On-broad Quality control, control results available either memory or display.
Technical Parameters:
Measuring Mode: Kinetics, End point, Fixed time, Differential, Absorbance, Multi-standard.
Light source: 6v/10w Halogen Lamp, life Span>3000 hours.
Standard filter: 340nm, 405nm, 505nm, 546nm, 578nm, 620nm, 670nm and one free position.
Band width: ≤ 8nm.
Linearity range: 0.000-3.000ABS.
Aspiration volume: 200-1400UL.
Flow cell: 32UL, Optical diameter: 1cm.
Cross contamination rate: ≤ 1%.
Temperature control: 25º C, 30º C, 37º C, ± 0.1º C and be controlled by peliter.
Language: English or any language on request.
Output: Built-in printer, RS232 for additional PC.
Display: 240*128LCD.
Power supply: AC220V± 10%, 50/60Hz.
Dimension: 430(L)mm× 320(W)mm× 220(H)mm.
Net weight: 9.0kg.
************************************************** ******
Type: Fully automated, desktop, random access, clinical chemistry analyzer
Throughput: 130 tests / hour, up to 200 tests / hour with ISE (optional)
Test Mode: End point, Fixed time (two point), Kinetics (velocity), Immuno assays; Monochromatic, Bi-chromatic & Multi-chromatic; Linearity & Nonlinearity, Single / Dual Reagents, Monochromatic / Bi-chromatic testing
Test Range: Clinical Biochemistry, Specific protein, ISE, Therapeutic medicine, Drug abuse, Urine/ Cerebrospinal fluid
Sample tray: 28 sample positions, any position can be aligned as STAT which can be inserted at any time during the routine examination
Sample tubes: Sample cup, Vacuum blood collection tube, plastic tubes are all available
Sample volume: 2µ L~35µ L, programmed in 0.1µ L step
Reagent tray: 56 reagent positions for R1 and R2
Refrigeration: 24 hours non-stop cooling with Peltier element maintaining temperature 4~15º C; Controlled by a separately switch
Reagent bottle: 15ml, 35ml and 40ml; Slope bottom design
Reagent volume: 150µ L ~300µ L, programmed in 1µ L step, reagent blank can be deducted automatically when testing
Sample & Reagent Probe: Integrated multi-function reagent needle with liquid surface detection, collision protection, reagent pre-heating function, reagent residual volume monitoring and alarming function
Probe Cleaning: Inner and outer wall auto washing with warm water, carry over < 0.1%
Syringe: American imported, long-life span, high-accuracy, durable and maintenance free
Optional item: Bar code reader
Reaction tray: 48 reaction cuvettes, 6mm optical path, plastic cuvette, semi-permanent
Reaction volume: 150µ L ~300µ L
Reaction time: About 10 minutes
Temperature: 37º C, fluctuation + 0.1º C
Light source: Halogen lamp, 6V/10W, life span ≥ 3000 hours
Wavelength: 340nm, 405nm, 450nm, 492nm, 505nm, 546nm, 578nm, 620nm, 670nm, 700nm
Absorbance range: 0.000 ABS ~3.000 ABS
Resolution: 0.001ABS
Calibration & Quality Control
Calibration mode: Linear (one-point, two-point and multi-point), Logit-Log4P, Logit-Log5P, Spline curve, Exponential Function, Polynomial, Parabola
QC rules: Westgard Multi-rule, Cumulative Sum Check, Twin Plot, 3 concentration levels QC
QC mode: Real time, Intra day & Inter day QC
************************************************** ******
Stream line design, nice appearance
More than 70 items including routine and STAT parameters
Reagent system open
Two reading modes: Cuvetle & Flow cell
RS232 interface, intelligent software, 1200testing results in memory can be printed
Built-in thermo printer
Technical Parameters:
Light source: 12v/20w Halogen Lamp, life Span>2000 hours
Standard filter: 340nm, 405nm, 505nm, 546nm, 578nm, 620nm, 670nm and one free position
Band width: ≤ 8nm
Linearity range: 0.000-3.000ABS
Aspiration volume: 200-1400UL
Flow cell: 30UL, Optical diameter: 1cm
Cross contamination rate: ≤ 2%
Operational temperature: 10~40º C
Temperature control: 25º C, 30º C, 37º C, ± 0.1º C and be controlled by peliter
Measuring Mode: Kinetics, End point, Fixed time, Differential, Absorbance, Multi-standard, Double wavelength
Display: 240*128LCD
QC: Statistically analyzed of QC DATA; QC chart can be displayed and memorized Standard RS-232 interface
RH: ≤ 85%
Power supply: AC220V± 10%, 50Hz± 2%
Dimension: 460(L)mm× 380(W)mm× 220(H)mm
Net weight: 14kg
************************************************** *******
Main Specifications for GF-3000 21-Phase Trisection Automatic Blood Cell/ Hematology Analyzer
Working principle: Resistance calculation, cyanogen ferrihemoglobin method.
Test parameter: Leucocyte three categories, 21-parameter
Sample dosage: Automatic pre-diluted peripheral blood 20UL, blood coagulation 13UL.
Working mode: Double-passage measure+ independent hemoglobin test system
Aperture of micro-pore WBC 100um, RBC/PLT 70um
Working speed: The time from sampling to test is less than 1 min. It can work for the whole day with dormancy function.
Result storage: Automatically store 1250 reports containing results of 3 histograms
Quality inspection manner: X-B, L-J graphic
Signing manner: Manual signing and automatic signing
Reagent dosage: Diluent 25ml/sample
Hemolytic agent 0.5ml or 0.36ml/sample
Rinse solution: 6ml/sample
Index
Parameter
Linearity extension
Precision (CV value)
Leucocyte number
WBC(109 /L)
0.00-99.9
2.0% (5.0-15.0x109 /L)
Red blood cell number
RBC(1012 /L)
0.00-9.99
1.5% (3.5-6.0x1012/L)
Hemoglobin
HGB (g/L)
0.0-300.0
1.5% (110-180g/L)
Average red blood cell cubage
MCV (fL)
40.0-150.0
0.5% (80.0-110.0Fl)
Haematoblast number
PLT (109 /L)
0.0-999.0
4.0%(100-500x109 /L)
Across pollution WBC, RBC, HGB≤ 0.5%, PLT≤ 1%
Monitor 640x480 resolution, large screen 8 colored LCD
Input and output entrance, one parallel printer port, one RS232 port (network function), one RS232 port (coder available for sample number listing), one keyboard port
Print report, efficient heat sensitive printing, paper width 5.0cm, adopting Epson stylus printer, plug-and-play, the digital management software is also adoptable.
Working environment: Temperature 15º C-35º C, humidity 10%-90%, used in high altitude.
Power supply: 220V± 15%, 50Hz ± 2%
Dimensions: 460 mm (H) x 390 mm (W) x 390 mm (D)
Weight 25kg
************************************************** *********
Faith-3000 is a random access automatic biochemistry analyzer. It adapts 120PCS cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical indicates of patient.
Main specifications:
1. Test speed: 300 tests/hour
2. Assay types: End-point assay, rate assay, fixed-point assay...
3. Assay items: 45 items each time
4. Cuvette: 120 reaction bottles; Light path length: 6mm
5. Total reaction volume: 180UL minimum
6. Sample volume: 2 to 50 microliters
7. Reagent volume: R1 25UL-300UL; R2 10UL-150UL
8. Reaction time: About 10 minutes
9. Wavelength: 340, 380, 405, 450, 510, 546, 578, 600, 660, 700, 800nm
10. Quality control: 6 types per test item
Loading sample system
1. The loading apparatus(syringe) is imported from German microsyring which is assured the accuracy of minimum sample.
2. The probe needle connected the high-precision syringe is washed inside and outside by pressure water (warm or normal temperature) or cleaning liquid which are pumped.
Liquid level sense system
1. The probe has the coat of tfl can reduce across-polluter evidently.
2. The system solve the problem of reaction cups thoroughly by the particular design which got rid of washing system.
3. The urgent sample can be tested preferentially at any time.
Separate whisk arm
1. Mix the reaction solution to urge reacting adequately
2. Separate needle avoids across-polluter.
Washing station
1.8 washing needles connected with 4 pumps.
2. High pressure water or cleaning liquid
3. Synchronous and in time with the test.
Cold storage and calefaction system
1. The sample and reagent can be hold longtime stabilization by semiconductor (8 degrees under the rt) or compressor refrigeration. 2. The analyzer can lodge 60 sample cups and 45 reagent bottles.
3. The intelligent temperature system will heat up the reaction solution to the appropriate reaction temperature
Optical system
1. The system include light filter, optical fiber, 120 reaction bottles and photoelectric receiver which are imported.
2. Reaction time is about 10 minutes.
3. The point of reading can be set freely.
Operation system
1. The software use the language of Chinese or English.
2. The function include testing calculations, sample blank correction, correlative, panic, dynamic and repeat run range judgements; Reagent absorbance and reaction mixture absorbance check; Abnormal value, pending and repeat run lists; Report format printing.
Complete customer service
1. We provide fine products and all-sided service for our customers.
2. We have highly trained customer service and professional technical support staff to slove any possible problems customers may have.
3. We are willing to establish good business relations with companies all over the world.
تعليق