جهاز جديد لإيجاد الوريد من أجل سحب الدم Vein Viewer

تقليص
X
 
  • تصفية - فلترة
  • الوقت
  • عرض
إلغاء تحديد الكل
مشاركات جديدة

  • #76
    مره حلوو بجد تقنيه ممتازه ياليت يتوفر بكل المستشفيات
    يعطيك العافيه

    تعليق


    • #77
      جهاز عد خلايا الدم الأتوماتيكى 20 براميتر
      Blood Cell Counter 20 Parameters
      *****************************************

      ""Swelab Alfa basic"" is the analyzer for mainstream laboratories that prioritrizes quality results from a quality hematology system.

      • The smart BCD interface starts and administers control samples seconds.

      • Alfa standard also comes with a built – in mixer,Thanks to the unique MCI adapter , a full blood screen can be made from a single drop of blood.

      Screen : b/w touch
      Parameters : 20
      Automatic cleaning : yes
      Printer : yes
      External barcode reader : yes


      More Specfications :

      • Measuring principle RBC,WBC,PLT : Impedance
      • Measuring principle HGB : photometer , Cyanide free method 535 nm+5nm
      • Programmable WBC discriminator : yes
      • Sampling System : closed shear valve
      • Parameters reported: RBC, MCV, HCT,PLT,MPV,HGB,MCH,MCHC,WBC,RDW%,LYMPH abs, MID abs, GRAN abs,LYMPH %, MID %, GRAN% , RDW abs, PDW abs, LPCR , PCT
      • Size distributions printed for : RBC,PLT and WBC diff
      • Aspirated blood volume (open tubes) : <100 ul
      • Blood volume using the Micro capillary Inlet (MCI) : 20 ul
      • Pre- diluted mode : 1:200 to 1:300 using min. 20 ul e.g. 20 ul to 4.5 ml diluents (1 : 225)
      • LCD : Graphical b/w touch screen, 240 columns x 320 rows
      • Keyboard : Virtual incorporated keyboard ( external keyboard possible)
      • Number of samples per hour : 67 samples
      • HGB correction on high WBC counts: Yes
      • Warning flags on parameter abnormalities : Yes
      • Automatic HGB blank on each sample : Yes
      • Bar code reader input : Yes
      • Serial output : Yes
      • Power consumption ( Stand – by) : Max 20 V A
      • Built in test / adjustment programs : Yes
      • Statistical calculation program for patient flow up

      Company : Boule
      MADE IN SWEDEN

      للاتصال بنا
      ***********
      Mob: 014-2385783
      E-mail : invitro2012@gmail.com
      ************************************
      موقعنا على الفيس بوك
      *********************
      https://www.facebook.com/profile.php?id=100002594646761

      تعليق


      • #78
        جهاز عد خلايا الدم الأتوماتيكى 20 براميتر
        Blood Cell Counter 20 Parameters
        *****************************************

        ""Swelab Alfa basic"" is the analyzer for mainstream laboratories that prioritrizes quality results from a quality hematology system.

        • The smart BCD interface starts and administers control samples seconds.

        • Alfa standard also comes with a built – in mixer,Thanks to the unique MCI adapter , a full blood screen can be made from a single drop of blood.

        Screen : b/w touch
        Parameters : 20
        Automatic cleaning : yes
        Printer : yes
        External barcode reader : yes


        More Specfications :

        • Measuring principle RBC,WBC,PLT : Impedance
        • Measuring principle HGB : photometer , Cyanide free method 535 nm+5nm
        • Programmable WBC discriminator : yes
        • Sampling System : closed shear valve
        • Parameters reported: RBC, MCV, HCT,PLT,MPV,HGB,MCH,MCHC,WBC,RDW%,LYMPH abs, MID abs, GRAN abs,LYMPH %, MID %, GRAN% , RDW abs, PDW abs, LPCR , PCT
        • Size distributions printed for : RBC,PLT and WBC diff
        • Aspirated blood volume (open tubes) : <100 ul
        • Blood volume using the Micro capillary Inlet (MCI) : 20 ul
        • Pre- diluted mode : 1:200 to 1:300 using min. 20 ul e.g. 20 ul to 4.5 ml diluents (1 : 225)
        • LCD : Graphical b/w touch screen, 240 columns x 320 rows
        • Keyboard : Virtual incorporated keyboard ( external keyboard possible)
        • Number of samples per hour : 67 samples
        • HGB correction on high WBC counts: Yes
        • Warning flags on parameter abnormalities : Yes
        • Automatic HGB blank on each sample : Yes
        • Bar code reader input : Yes
        • Serial output : Yes
        • Power consumption ( Stand – by) : Max 20 V A
        • Built in test / adjustment programs : Yes
        • Statistical calculation program for patient flow up

        Company : Boule
        MADE IN SWEDEN